Electrophysiology
Qubit Systems' latest series
of sensors are designed to investigate electrophysiological aspects of human
physiology in a completely safe and non-invasive manner. Where required, disposable
electrodes are supplied, each of which has a gel backing that attaches the electrode
to the subject's skin. Signals from the skin are transmitted through optically
isolated circuitry, and power for the sensors is transformed from AC to low voltage
DC, so there is never any risk of electric shock.
Numerous investigations
are possible with each of the sensors, which may be purchased individually or
as a package with a LabPro interface and Logger Pro software. The sensors provide
an excellent complement to the Human Respirometry Package for comprehensive investigations
of subjects under a variety of conditions.
|
The EKG sensor measures cardiac
waveforms generated by electrical activity of the heart muscle. The cyclical
contraction and relaxation of the atria and ventricles creates an electrical
current that moves through the body, which can be measured by electrodes
attached to the skin. The EKG sensor comes with 3 electrode cables and a
set of 100 disposable electrodes.
|
|
|
Qubit Systems' surface electromyograph
(EMG) records the electrical activity of muscles. Normal muscle tissue is
electrically silent when relaxed. When it is active during a contraction,
an electrical current is generated that can be measured at the surface of
the skin. The strength of the signal depends upon the number of muscle motor
units recruited to contract the muscle. An audible signal is produced as
the muscle is flexed so that the subject receives a visual and an aural indication
of the strength of the contraction.
|
|
|
Qubit Systems' strain-gage
based isometric S216 Hand Dynamometer is designed for use with the LabPro
interface and Logger Pro software in a variety of experiments, and may be
combined with the S210 EMG sensor for comprehensive studies of muscle activity.
The dynamometer is factory calibrated in Newtons and kilograms force. It
measures grip strength, relative strength of the left and right hand, muscle
fatigue and endurance. It also has grips for measuring finger strength.
|
|
|
The S220 Galvanic Skin Response
(GSR) Sensor measures the psycho-galvanic reflex. This reflex generates a
change in skin conductivity during periods of stress, excitement or shock.
The GSR sensor monitors skin conductivity between two reusable electrodes
attached to 2 fingers of one hand. While the subject is at rest, a steady
background signal will be monitored by C901 Logger Pro software on the computer
screen. It is also possible to obtain an audible signal.
|
|
|
Qubit Systems' S225 Electrooculograph
(EOG) is used to monitor eye movement of a stationary subject. A reference
electrode is placed on the forehead, electrodes are placed on the right and
left temples for lateral eye movement detection, and above and below an eye
for vertical eye movement detection. Lateral movement and vertical movement
are plotted on different channels as voltages, or the EOG can be calibrated
for each subject to provide angles of eye movement in both the horizontal
and vertical plane.
|
|
NOTE: All human electrophysiology and human
respiratory monitoring products provided by Qubit Systems Inc. are not appropriate
for medical or clinical applications.
|